Full TGIF Record # 224214
Item 1 of 1
DOI:10.2136/vzj2012.0139
Web URL(s):https://acsess.onlinelibrary.wiley.com/doi/10.2136/vzj2012.0139
    Last checked: 02/09/2024
    Access conditions: Item is within a limited-access website
https://acsess.onlinelibrary.wiley.com/doi/epdf/10.2136/vzj2012.0139
    Last checked: 02/09/2024
    Requires: PDF Reader
    Access conditions: Item is within a limited-access website
Publication Type:
i
Refereed
Author(s):Qu, W.; Bogena, H. R.; Huisman, J. A.; Vereecken, H.
Author Affiliation:Agrosphere Institute (IBG-3), Jülich, Germany
Title:Calibration of a novel low-cost soil water content sensor based on a ring oscillator
Section:Special section: Soil water sensors and measurement technologies
Other records with the "Special section: Soil water sensors and measurement technologies" Section
Source:Vadose Zone Journal. Vol. 12, No. 2, May 2013, p. [1-10].
Publishing Information:Madison, Wisconsin: Soil Science Society of America
# of Pages:10
Related Web URL:https://dl.sciencesocieties.org/publications/vzj/abstracts/12/2/vzj2012.0139
    Last checked: 11/10/2016
    Access conditions: Item is within a limited-access website
    Notes: Abstract only
https://dl.sciencesocieties.org/publications/vzj/articles/12/2/vzj2012.0139?show-t-f=tables&wrapper=n
    Last checked: 11/10/2016
    Access conditions: Item is within a limited-access website
    Notes: Tables only
https://dl.sciencesocieties.org/publications/vzj/articles/12/2/vzj2012.0139?show-t-f=figures&wrapper=n
    Last checked: 11/10/2016
    Access conditions: Item is within a limited-access website
    Notes: Figures only
Keywords:TIC Keywords: Calibrations; Product evaluation; Soil moisture sensors; Temperatures
Trade Names:Spade
Abstract/Contents:"We evaluated the sensor-to-sensor variability of the SPADE soil moisture sensor and found an increase in accuracy when a sensor-specific calibration was used to relate sensor response and dielectric permittivity. The effect of temperature on sensor response was accounted for by a correction function that was successfully tested on soil material. Wireless sensor networks are becoming more popular to monitor spatial and temporal variability of soil water content. The aim of this paper is to calibrate and test the newly developed SPADE sensor for wireless sensor network applications. During calibration, the measured sensor output is related to dielectric permittivity using an empirical calibration in liquids with well-defined permittivities. Using these calibration measurements, we have evaluated sensor-to-sensor variability and compared the accuracy of a universal calibration between sensor output and permittivity with a sensor-specific calibration. Our results showed that the sensor-to-sensor variability of the SPADE sensor is larger than sensor noise and that a sensor-specific calibration can improve the accuracy of soil water content estimation as compared to a single universal calibration. To quantify the effect of temperature on the sensor output, we have derived a temperature correction function in a temperature range from 5 to 40°C. The results showed an underestimation for low temperatures (5 to 25°C) and an overestimation for high temperatures (25 to 40°C). A second-order polynomial function was fitted to the measurements with good agreement (R2 = 0.9831, RMSE = 0.1489). The transferability of the temperature correction function from reference liquids to soils was verified using saturated coarse sand and a silty loam soil sample. The temperature-corrected SPADE sensor measurements in soil showed good agreement with TDR measurements and corresponded well with theoretical predictions from a dielectric mixing model."
Language:English
References:37
Note:Equations
Pictures, color
Figures
Tables
Graphs
ASA/CSSA/SSSA Citation (Crop Science-Like - may be incomplete):
Qu, W., H. R. Bogena, J. A. Huisman, and H. Vereecken. 2013. Calibration of a novel low-cost soil water content sensor based on a ring oscillator. Vadose Zone J. 12(2):p. [1-10].
Fastlink to access this record outside TGIF: https://tic.msu.edu/tgif/flink?recno=224214
If there are problems with this record, send us feedback about record 224214.
Choices for finding the above item:
DOI: 10.2136/vzj2012.0139
Web URL(s):
https://acsess.onlinelibrary.wiley.com/doi/10.2136/vzj2012.0139
    Last checked: 02/09/2024
    Access conditions: Item is within a limited-access website
https://acsess.onlinelibrary.wiley.com/doi/epdf/10.2136/vzj2012.0139
    Last checked: 02/09/2024
    Requires: PDF Reader
    Access conditions: Item is within a limited-access website
Find Item @ MSU
MSU catalog number: b4896766
Find from within TIC:
   Digitally in TIC by record number.
Request through your local library's inter-library loan service (bring or send a copy of this TGIF record)