Full TGIF Record # 224320
Item 1 of 1
DOI:10.2136/vzj2003.6110
Web URL(s):https://acsess.onlinelibrary.wiley.com/doi/10.2136/vzj2003.6110
    Last checked: 02/15/2024
    Access conditions: Item is within a limited-access website
https://acsess.onlinelibrary.wiley.com/doi/epdf/10.2136/vzj2003.6110
    Last checked: 02/15/2024
    Requires: PDF Reader
    Access conditions: Item is within a limited-access website
Publication Type:
i
Refereed
Author(s):Jalbert, Marc; Dane, Jacob H.
Author Affiliation:Department of AGronomy and Soils, Auburn University, AL
Title:A handheld device for intrusive and nonintrusive field measurements of air permeability
Section:Special section - Advances in measurement and monitoring methods
Other records with the "Special section - Advances in measurement and monitoring methods" Section
Source:Vadose Zone Journal. Vol. 2, No. 4, November 2003, p. 611-617.
Publishing Information:Madison, Wisconsin: Soil Science Society of America
# of Pages:7
Related Web URL:https://dl.sciencesocieties.org/publications/vzj/abstracts/2/4/611
    Last checked: 11/10/2016
    Access conditions: Item is within a limited-access website
    Notes: Abstract only
Keywords:TIC Keywords: Air movement; Evaluative methods; Organic matter; Permeability; Physical properties of soil; Product profile; Sandy loam soils; Soil analysis; Soil texture
Abstract/Contents:"Air permeability is an easy to measure soil parameter that is of direct importance in gas transport studies. Its values can also be used as indicators of soil hydraulic conductivity. Near the soil surface, both air and water permeability values are important for hydrological and agricultural studies involving, for example, soil aeration and water runoff during rainfall events. We provide a design of a rugged, lightweight, handheld, single-reading device allowing for fast measurements of air permeability near the soil surface. The device makes use of two interchangeable air probes. The contact probe, well documented in the petroleum engineering literature, is proposed as an addition to the traditional insertion probe. The advantages and drawbacks of each probe type are discussed briefly. Central to the in situ measurement of air permeability is the concept of the probe geometric factor. Empirical relationships are presented to make the application of this concept more amenable. Relative differences in air permeability values obtained with the two probes seem to be acceptable for permeability measurements. Even though in most cases contact probe air permeability values were higher than insertion probe values, no clear trend existed. The differences were attributed to differences in soil compaction, bypass flow, and different measurement volumes associated with the two probe types. For the flow rates and pressures encountered during the measurements, the flow rate behaved as a linear function of the pressure gradient. In other words, the assumed Darcy-type equation was applicable."
Language:English
References:23
Note:Equations
Figures
Tables
Graphs
ASA/CSSA/SSSA Citation (Crop Science-Like - may be incomplete):
Jalbert, M., and J. H. Dane. 2003. A handheld device for intrusive and nonintrusive field measurements of air permeability. Vadose Zone J. 2(4):p. 611-617.
Fastlink to access this record outside TGIF: https://tic.msu.edu/tgif/flink?recno=224320
If there are problems with this record, send us feedback about record 224320.
Choices for finding the above item:
DOI: 10.2136/vzj2003.6110
Web URL(s):
https://acsess.onlinelibrary.wiley.com/doi/10.2136/vzj2003.6110
    Last checked: 02/15/2024
    Access conditions: Item is within a limited-access website
https://acsess.onlinelibrary.wiley.com/doi/epdf/10.2136/vzj2003.6110
    Last checked: 02/15/2024
    Requires: PDF Reader
    Access conditions: Item is within a limited-access website
Find Item @ MSU
MSU catalog number: b4896766
Find from within TIC:
   Digitally in TIC by record number.
Request through your local library's inter-library loan service (bring or send a copy of this TGIF record)