Content Type:Turftwister Q & A
Corporate Author(s):USGA Green Section
Title:[Sound depth in bunkers]
Source:USGA Green Section Record. Vol. 45, No. 4, July/August 2007, p. Back cover.
Publishing Information:Far Hills, NJ: United States Golf Association, Green Section
# of Pages:1
Question:"To what depth should sand be installed in a bunker? Is there a way to determine an appropriate depth?"
Source of Question:West Virginia
Answer/Response:"Laboratory testing can eliminate much of the guesswork. An accredited lab can determine the level of moisture retention by examining particle size distribution and saturated hydraulic conductivity. The degree to which moisture will be retained can affect the firmness of the bunker sand and whether or not drainage-related problems will occur. If the depth of the sand is too shallow, anaerobic conditions could develop. The laboratory can help determine to what depth sand should be installed."
Keywords:TIC Keywords: Sand; Bunkers; Deep bunkers; Installation; Soil water retention; Particle size; Saturated hydraulic conductivity
Language:English
References:0
Note:Pictures, color
ASA/CSSA/SSSA Citation (Crop Science-Like - may be incomplete):
USGA Green Section. 2007. [Sound depth in bunkers]. USGA Green Sec. Rec. 45(4):p. Back cover.
Fastlink to access this record outside TGIF: https://tic.msu.edu/tgif/flink?recno=125436
If there are problems with this record, send us feedback about record 125436.
Choices for finding the above item:
Web URL(s):
https://gsrpdf.lib.msu.edu/?file=/2000s/2007/0707BC.pdf
    Last checked: 01/26/2017
    Requires: PDF Reader
Find Item @ MSU
MSU catalog number: SB 433.15 .U84
Request through your local library's inter-library loan service (bring or send a copy of this TGIF record)