DOI: | 10.1016/0378-3774(90)90089-H |
Web URL(s): | http://ac.els-cdn.com/037837749090089H/1-s2.0-037837749090089H-main.pdf?_tid=09022eb8-aa8f-11e6-a2aa-00000aab0f27&acdnat=1479144379_1e75abf5a82861edc39f4ac1b0473e99 Last checked: 11/14/2016 Requires: PDF Reader Access conditions: Item is within a limited-access website http://www.sciencedirect.com/science/article/pii/037837749090089H Last checked: 12/15/2016 Requires: PDF Reader Access conditions: Item is within a limited-access website |
Publication Type:
| Refereed |
Author(s): | Nesmith, D. S.;
Miller, A.;
Ritchie, J. T. |
Author Affiliation: | Nesmith and Ritchie: Crop and Soil Science Department, Michigan State University, East Lansing; Miller: Professional Eng., Royal Oak, MI |
Title: | An irrigation system for plots under a rain shelter |
Source: | Agricultural Water Management. Vol. 17, No. 4, March 1990, p. 409-414. |
Publishing Information: | [Amsterdam]: Elsevier Scientific Pub. |
# of Pages: | 6 |
Keywords: | TIC Keywords: Irrigation efficiency; Irrigation system design; Irrigation uniformity; Weather shelters
|
Abstract/Contents: | "Rain shelters are important research tools for studying the soil-plant-water system. Much attention has been given to the design of these structures for the purpose of keeping water off plots; however, irrigation under these structures has not been widely reported. A simple irrigation system was developed from readily available materials for use under a large rain shelter. Solid set, low-volume sprinklers frequently used by the turf industry were employed. Performance and evaluation tests showed that the system had uniform water distribution over the main-plot area of 4.6 × 6.2 m2 plots, while minimizing overlap between adjacent plots. The water application rate achieved was approximately 25 mm h-1 for individual units. Christiansen uniformity coefficients (CUC) were 83 to 85% for tested units. Water falling a distance of 0.7 m or less outside of a plot was less than 3 mm h-1, while at greater distances it was essentially zero." |
Language: | English |
References: | 7 |
Note: | Figures Tables |
| ASA/CSSA/SSSA Citation (Crop Science-Like - may be incomplete): Nesmith, D. S., A. Miller, and J. T. Ritchie. 1990. An irrigation system for plots under a rain shelter. Agric. Water Manage. 17(4):p. 409-414. |
| Fastlink to access this record outside TGIF: https://tic.msu.edu/tgif/flink?recno=238224 |
| If there are problems with this record, send us feedback about record 238224. |
| Choices for finding the above item: |
| DOI: 10.1016/0378-3774(90)90089-H |
| Web URL(s): http://ac.els-cdn.com/037837749090089H/1-s2.0-037837749090089H-main.pdf?_tid=09022eb8-aa8f-11e6-a2aa-00000aab0f27&acdnat=1479144379_1e75abf5a82861edc39f4ac1b0473e99 Last checked: 11/14/2016 Requires: PDF Reader Access conditions: Item is within a limited-access website http://www.sciencedirect.com/science/article/pii/037837749090089H Last checked: 12/15/2016 Requires: PDF Reader Access conditions: Item is within a limited-access website |
| MSU catalog number: b2205878a |
| Find from within TIC: Digitally in TIC by record number. |
| Request through your local library's inter-library loan service (bring or send a copy of this TGIF record) |